12  2010 . 13:18:38 MSD

Configuration summary
---------------------------

Server name.....................office-pr
Adaptec Storage Manager agent...6.40.00 (18530)
Adaptec Storage Manager console.6.40.00 (18530)
Number of controllers...........1
Operating system................Windows

Configuration information for controller 1
-------------------------------------------------------
Type............................Controller
Model...........................Adaptec 5445Z
Controller number...............1
Physical slot...................4
Installed memory size...........512 MB
Serial number...................9A25111EF49
Boot ROM........................5.2-0 (17912)
Firmware........................5.2-0 (17912)
Device driver...................5.2-0 (17911)
Controller status...............Optimal
ZMM status......................Optimal
Background consistency check....Enabled
Background consistency check period30 days
Copy back.......................Enabled
Controller temperature..........Normal (62C / 143F)
Default logical drive task priorityHigh
Performance mode................OLTP / database
Number of logical devices.......2
Number of hot-spare drives......2
Number of ready drives..........0
Number of drive(s) assigned to MaxIQ cache0
Maximum drives allowed for MaxIQ cache8
NCQ status......................Enabled
Stay awake status...............Disabled
Internal drive spinup limit.....0
External drive spinup limit.....0
Phy 0...........................3.00 Gb/s
Phy 1...........................3.00 Gb/s
Phy 2...........................3.00 Gb/s
Phy 3...........................3.00 Gb/s
Phy 4...........................No device attached
Phy 5...........................No device attached
Phy 6...........................No device attached
Phy 7...........................No device attached

Logical device..................0
Logical device name.............RAID1
RAID level......................5
Data space......................8369,99 GB
Parity space....................1395 GB
Date created....................10/07/2010
Stripe size.....................256K
Interface type..................Serial ATA
State...........................Optimal
Read-cache mode.................Enabled
Preferred MaxIQ cache setting...Enabled
Actual MaxIQ cache setting .....Disabled
Write-cache mode................Enabled (write-back)
Write-cache setting.............Enabled (write-back)
Partitioned.....................No
Protected by hot spare..........Yes
Bootable........................Yes
Bad stripes.....................No
Power Status....................Disabled
Power State.....................Active
Reduce RPM timer................Never
Power off timer.................Never
Verify timer....................Never
Segment 0.......................Present: controller 1, enclosure 0, slot 0, S/N WD-WMAVU2099743
Segment 1.......................Present: controller 1, enclosure 0, slot 1, S/N WD-WMAVU2059348
Segment 2.......................Present: controller 1, enclosure 0, slot 2, S/N WD-WMAVU1887068
Segment 3.......................Present: controller 1, enclosure 0, slot 3, S/N WD-WMAVU2061798
Segment 4.......................Present: controller 1, enclosure 0, slot 4, S/N WD-WMAVU1886786
Segment 5.......................Present: controller 1, enclosure 0, slot 5, S/N WD-WMAVU1892544
Segment 6.......................Present: controller 1, enclosure 0, slot 6, S/N WD-WMAVU2060704

Logical device..................1
Logical device name.............RAID2
RAID level......................5
Data space......................8369,99 GB
Parity space....................1395 GB
Date created....................10/07/2010
Stripe size.....................256K
Interface type..................Serial ATA
State...........................Optimal
Read-cache mode.................Enabled
Preferred MaxIQ cache setting...Enabled
Actual MaxIQ cache setting .....Disabled
Write-cache mode................Enabled (write-back)
Write-cache setting.............Enabled (write-back)
Partitioned.....................No
Protected by hot spare..........Yes
Bootable........................No
Bad stripes.....................No
Power Status....................Disabled
Power State.....................Active
Reduce RPM timer................Never
Power off timer.................Never
Verify timer....................Never
Segment 0.......................Present: controller 1, enclosure 0, slot 7, S/N WD-WMAVU2059336
Segment 1.......................Present: controller 1, enclosure 0, slot 8, S/N WD-WMAVU2059353
Segment 2.......................Present: controller 1, enclosure 0, slot 9, S/N WD-WMAVU2059308
Segment 3.......................Present: controller 1, enclosure 0, slot 10, S/N WD-WMAVU1886585
Segment 4.......................Present: controller 1, enclosure 0, slot 11, S/N WD-WMAVU1891678
Segment 5.......................Present: controller 1, enclosure 0, slot 12, S/N WD-WMAVU1891756
Segment 6.......................Present: controller 1, enclosure 0, slot 13, S/N WD-WMAVU2099803

Serial attached SCSI
-----------------------
Type............................Disk drive
Vendor..........................WDC
Model...........................WD15EARS-00Z
Serial Number...................WD-WMAVU2099743
Firmware level..................80.00A80
Reported channel................0
Reported SCSI device ID.........8
Interface type..................Serial ATA
Size............................1397,265 GB
Location........................Enclosure 0, slot 0
Negotiated transfer speed.......3.00 Gb/s
State...........................Optimal
S.M.A.R.T. error................No
Write-cache mode................Write back
Hardware errors.................0
Medium errors...................0
Parity errors...................0
Link failures...................0
Aborted commands................1161
S.M.A.R.T. warnings.............0
Solid-state disk (non-spinning).false
MaxIQ cache capable.............false
MaxIQ cache assigned............false
NCQ status......................Enabled
Phy 0...........................3.00 Gb/s
Power State.....................Full rpm
Supported power states..........Full rpm, Powered off

Type............................Disk drive
Vendor..........................WDC
Model...........................WD15EARS-00Z
Serial Number...................WD-WMAVU2059348
Firmware level..................80.00A80
Reported channel................0
Reported SCSI device ID.........9
Interface type..................Serial ATA
Size............................1397,265 GB
Location........................Enclosure 0, slot 1
Negotiated transfer speed.......3.00 Gb/s
State...........................Optimal
S.M.A.R.T. error................No
Write-cache mode................Write back
Hardware errors.................0
Medium errors...................0
Parity errors...................0
Link failures...................0
Aborted commands................851
S.M.A.R.T. warnings.............0
Solid-state disk (non-spinning).false
MaxIQ cache capable.............false
MaxIQ cache assigned............false
NCQ status......................Enabled
Phy 0...........................3.00 Gb/s
Power State.....................Full rpm
Supported power states..........Full rpm, Powered off

Type............................Disk drive
Vendor..........................WDC
Model...........................WD15EARS-00Z
Serial Number...................WD-WMAVU1887068
Firmware level..................80.00A80
Reported channel................0
Reported SCSI device ID.........10
Interface type..................Serial ATA
Size............................1397,265 GB
Location........................Enclosure 0, slot 2
Negotiated transfer speed.......3.00 Gb/s
State...........................Optimal
S.M.A.R.T. error................No
Write-cache mode................Write back
Hardware errors.................0
Medium errors...................0
Parity errors...................0
Link failures...................0
Aborted commands................1560
S.M.A.R.T. warnings.............0
Solid-state disk (non-spinning).false
MaxIQ cache capable.............false
MaxIQ cache assigned............false
NCQ status......................Enabled
Phy 0...........................3.00 Gb/s
Power State.....................Full rpm
Supported power states..........Full rpm, Powered off

Type............................Disk drive
Vendor..........................WDC
Model...........................WD15EARS-00Z
Serial Number...................WD-WMAVU2061798
Firmware level..................80.00A80
Reported channel................0
Reported SCSI device ID.........11
Interface type..................Serial ATA
Size............................1397,265 GB
Location........................Enclosure 0, slot 3
Negotiated transfer speed.......3.00 Gb/s
State...........................Optimal
S.M.A.R.T. error................No
Write-cache mode................Write back
Hardware errors.................0
Medium errors...................3
Parity errors...................0
Link failures...................0
Aborted commands................2006
S.M.A.R.T. warnings.............0
Solid-state disk (non-spinning).false
MaxIQ cache capable.............false
MaxIQ cache assigned............false
NCQ status......................Enabled
Phy 0...........................3.00 Gb/s
Power State.....................Full rpm
Supported power states..........Full rpm, Powered off

Type............................Disk drive
Vendor..........................WDC
Model...........................WD15EARS-00Z
Serial Number...................WD-WMAVU1886786
Firmware level..................80.00A80
Reported channel................0
Reported SCSI device ID.........12
Interface type..................Serial ATA
Size............................1397,265 GB
Location........................Enclosure 0, slot 4
Negotiated transfer speed.......3.00 Gb/s
State...........................Optimal
S.M.A.R.T. error................No
Write-cache mode................Write back
Hardware errors.................0
Medium errors...................0
Parity errors...................0
Link failures...................0
Aborted commands................1577
S.M.A.R.T. warnings.............0
Solid-state disk (non-spinning).false
MaxIQ cache capable.............false
MaxIQ cache assigned............false
NCQ status......................Enabled
Phy 0...........................3.00 Gb/s
Power State.....................Full rpm
Supported power states..........Full rpm, Powered off

Type............................Disk drive
Vendor..........................WDC
Model...........................WD15EARS-00Z
Serial Number...................WD-WMAVU1892544
Firmware level..................80.00A80
Reported channel................0
Reported SCSI device ID.........13
Interface type..................Serial ATA
Size............................1397,265 GB
Location........................Enclosure 0, slot 5
Negotiated transfer speed.......3.00 Gb/s
State...........................Optimal
S.M.A.R.T. error................No
Write-cache mode................Write back
Hardware errors.................0
Medium errors...................7
Parity errors...................0
Link failures...................0
Aborted commands................1116
S.M.A.R.T. warnings.............0
Solid-state disk (non-spinning).false
MaxIQ cache capable.............false
MaxIQ cache assigned............false
NCQ status......................Enabled
Phy 0...........................3.00 Gb/s
Power State.....................Full rpm
Supported power states..........Full rpm, Powered off

Type............................Disk drive
Vendor..........................WDC
Model...........................WD15EARS-00Z
Serial Number...................WD-WMAVU2060704
Firmware level..................80.00A80
Reported channel................0
Reported SCSI device ID.........14
Interface type..................Serial ATA
Size............................1397,265 GB
Location........................Enclosure 0, slot 6
Negotiated transfer speed.......3.00 Gb/s
State...........................Optimal
S.M.A.R.T. error................No
Write-cache mode................Write back
Hardware errors.................0
Medium errors...................0
Parity errors...................0
Link failures...................0
Aborted commands................1017
S.M.A.R.T. warnings.............0
Solid-state disk (non-spinning).false
MaxIQ cache capable.............false
MaxIQ cache assigned............false
NCQ status......................Enabled
Phy 0...........................3.00 Gb/s
Power State.....................Full rpm
Supported power states..........Full rpm, Powered off

Type............................Disk drive
Vendor..........................WDC
Model...........................WD15EARS-00Z
Serial Number...................WD-WMAVU2059336
Firmware level..................80.00A80
Reported channel................0
Reported SCSI device ID.........15
Interface type..................Serial ATA
Size............................1397,265 GB
Location........................Enclosure 0, slot 7
Negotiated transfer speed.......3.00 Gb/s
State...........................Optimal
S.M.A.R.T. error................No
Write-cache mode................Write back
Hardware errors.................0
Medium errors...................0
Parity errors...................0
Link failures...................0
Aborted commands................1082
S.M.A.R.T. warnings.............0
Solid-state disk (non-spinning).false
MaxIQ cache capable.............false
MaxIQ cache assigned............false
NCQ status......................Enabled
Phy 0...........................3.00 Gb/s
Power State.....................Full rpm
Supported power states..........Full rpm, Powered off

Type............................Disk drive
Vendor..........................WDC
Model...........................WD15EARS-00Z
Serial Number...................WD-WMAVU2059353
Firmware level..................80.00A80
Reported channel................0
Reported SCSI device ID.........16
Interface type..................Serial ATA
Size............................1397,265 GB
Location........................Enclosure 0, slot 8
Negotiated transfer speed.......3.00 Gb/s
State...........................Optimal
S.M.A.R.T. error................No
Write-cache mode................Write back
Hardware errors.................0
Medium errors...................1
Parity errors...................0
Link failures...................0
Aborted commands................1252
S.M.A.R.T. warnings.............0
Solid-state disk (non-spinning).false
MaxIQ cache capable.............false
MaxIQ cache assigned............false
NCQ status......................Enabled
Phy 0...........................3.00 Gb/s
Power State.....................Full rpm
Supported power states..........Full rpm, Powered off

Type............................Disk drive
Vendor..........................WDC
Model...........................WD15EARS-00Z
Serial Number...................WD-WMAVU2059308
Firmware level..................80.00A80
Reported channel................0
Reported SCSI device ID.........17
Interface type..................Serial ATA
Size............................1397,265 GB
Location........................Enclosure 0, slot 9
Negotiated transfer speed.......3.00 Gb/s
State...........................Optimal
S.M.A.R.T. error................No
Write-cache mode................Write back
Hardware errors.................0
Medium errors...................2
Parity errors...................0
Link failures...................0
Aborted commands................494
S.M.A.R.T. warnings.............0
Solid-state disk (non-spinning).false
MaxIQ cache capable.............false
MaxIQ cache assigned............false
NCQ status......................Enabled
Phy 0...........................3.00 Gb/s
Power State.....................Full rpm
Supported power states..........Full rpm, Powered off

Type............................Disk drive
Vendor..........................WDC
Model...........................WD15EARS-00Z
Serial Number...................WD-WMAVU1886585
Firmware level..................80.00A80
Reported channel................0
Reported SCSI device ID.........18
Interface type..................Serial ATA
Size............................1397,265 GB
Location........................Enclosure 0, slot 10
Negotiated transfer speed.......3.00 Gb/s
State...........................Optimal
S.M.A.R.T. error................No
Write-cache mode................Write back
Hardware errors.................0
Medium errors...................0
Parity errors...................0
Link failures...................0
Aborted commands................755
S.M.A.R.T. warnings.............0
Solid-state disk (non-spinning).false
MaxIQ cache capable.............false
MaxIQ cache assigned............false
NCQ status......................Enabled
Phy 0...........................3.00 Gb/s
Power State.....................Full rpm
Supported power states..........Full rpm, Powered off

Type............................Disk drive
Vendor..........................WDC
Model...........................WD15EARS-00Z
Serial Number...................WD-WMAVU1891678
Firmware level..................80.00A80
Reported channel................0
Reported SCSI device ID.........19
Interface type..................Serial ATA
Size............................1397,265 GB
Location........................Enclosure 0, slot 11
Negotiated transfer speed.......3.00 Gb/s
State...........................Optimal
S.M.A.R.T. error................No
Write-cache mode................Write back
Hardware errors.................0
Medium errors...................0
Parity errors...................0
Link failures...................0
Aborted commands................1234
S.M.A.R.T. warnings.............0
Solid-state disk (non-spinning).false
MaxIQ cache capable.............false
MaxIQ cache assigned............false
NCQ status......................Enabled
Phy 0...........................3.00 Gb/s
Power State.....................Full rpm
Supported power states..........Full rpm, Powered off

Type............................Disk drive
Vendor..........................WDC
Model...........................WD15EARS-00Z
Serial Number...................WD-WMAVU1891756
Firmware level..................80.00A80
Reported channel................0
Reported SCSI device ID.........20
Interface type..................Serial ATA
Size............................1397,265 GB
Location........................Enclosure 0, slot 12
Negotiated transfer speed.......3.00 Gb/s
State...........................Optimal
S.M.A.R.T. error................No
Write-cache mode................Write back
Hardware errors.................0
Medium errors...................7
Parity errors...................0
Link failures...................3
Aborted commands................693
S.M.A.R.T. warnings.............0
Solid-state disk (non-spinning).false
MaxIQ cache capable.............false
MaxIQ cache assigned............false
NCQ status......................Enabled
Phy 0...........................3.00 Gb/s
Power State.....................Full rpm
Supported power states..........Full rpm, Powered off

Type............................Disk drive
Vendor..........................WDC
Model...........................WD15EARS-00Z
Serial Number...................WD-WMAVU2099803
Firmware level..................80.00A80
Reported channel................0
Reported SCSI device ID.........21
Interface type..................Serial ATA
Size............................1397,265 GB
Location........................Enclosure 0, slot 13
Negotiated transfer speed.......3.00 Gb/s
State...........................Optimal
S.M.A.R.T. error................No
Write-cache mode................Write back
Hardware errors.................0
Medium errors...................0
Parity errors...................0
Link failures...................0
Aborted commands................844
S.M.A.R.T. warnings.............0
Solid-state disk (non-spinning).false
MaxIQ cache capable.............false
MaxIQ cache assigned............false
NCQ status......................Enabled
Phy 0...........................3.00 Gb/s
Power State.....................Full rpm
Supported power states..........Full rpm, Powered off

Type............................Disk drive
Vendor..........................WDC
Model...........................WD15EARS-00Z
Serial Number...................WD-WMAVU1891753
Firmware level..................80.00A80
Reported channel................0
Reported SCSI device ID.........30
Interface type..................Serial ATA
Size............................1397,265 GB
Location........................Enclosure 0, slot 22
Negotiated transfer speed.......3.00 Gb/s
State...........................Hot spare
S.M.A.R.T. error................No
Write-cache mode................Write back
Hardware errors.................0
Medium errors...................0
Parity errors...................0
Link failures...................0
Aborted commands................0
S.M.A.R.T. warnings.............0
Solid-state disk (non-spinning).false
MaxIQ cache capable.............false
MaxIQ cache assigned............false
NCQ status......................Enabled
Phy 0...........................3.00 Gb/s
Power State.....................Full rpm
Supported power states..........Full rpm, Powered off

Type............................Disk drive
Vendor..........................WDC
Model...........................WD15EARS-00Z
Serial Number...................WD-WMAVU2101016
Firmware level..................80.00A80
Reported channel................0
Reported SCSI device ID.........31
Interface type..................Serial ATA
Size............................1397,265 GB
Location........................Enclosure 0, slot 23
Negotiated transfer speed.......3.00 Gb/s
State...........................Hot spare
S.M.A.R.T. error................No
Write-cache mode................Write back
Hardware errors.................0
Medium errors...................7
Parity errors...................0
Link failures...................0
Aborted commands................1359
S.M.A.R.T. warnings.............0
Solid-state disk (non-spinning).false
MaxIQ cache capable.............false
MaxIQ cache assigned............false
NCQ status......................Enabled
Phy 0...........................3.00 Gb/s
Power State.....................Full rpm
Supported power states..........Full rpm, Powered off

Serial attached SCSI
-----------------------
Type............................Enclosure management device
Vendor..........................LSILOGIC
Model...........................SASX36 A.1
Firmware level..................7015
Enclosure status................Degraded
Fan 1 status....................Malfunctioning
Fan 2 status....................Malfunctioning
Fan 3 status....................Malfunctioning
Temperature sensor 1 status.....Normal (30C / 86F)


End of the configuration information for controller 1
-------------------------------------------------------